BEA WebLogic Server 7 Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 63
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
EJB
Development Using Borland
®
JBuilder
®
8 and BEA WebLogic Server
7.0
62
When did this happen
The error occurred when I tried to attach JBuilder with a running WebLogic Server.
Cause
The error occurred because either WebLogic is not running properly, or the debug parameters
provided to start WebLogic are not correct.
Solution
Check if WebLogic is running. If it is running, then check the debug parameters. If the debug
parameters are also correct, then check JBuilder Remote Debug configuration. From the
JBuilder menubar, click Run -> Configuration. Edit the Remote Debug entry. Click Debug
tab and check the address. Make sure that the port number provided in this address is the same
as the address provided in WebLogic debug options.
Useful links
JBuilder product documentation
http://info.borland.com/techpubs/jbuilder/jbuilder8/index1280x1024-ent.html
Optimizeit Suite product documentation
http://info.borland.com/techpubs/optimizeit/optimizeit5/index1280x1024.html
JBuilder tools and components
http://info.borland.com/jbuilder/resources/jbtools.html
JBuilder OpenTools
http://codecentral.borland.com/codecentral/ccweb.exe/prodcat?prodid=3&catid=11
JBuilder developers support
http://info.borland.com/devsupport/jbuilder/
JBuilder Frequently Asked Questions
http://community.borland.com/all/0,1435,c|3|10,00.html
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63

Comentarios a estos manuales

Sin comentarios